CLARITY RELEASE NOTES

  1. Main changes in the version 2.4 comparing to the version 2.3 * PDA module - integrated add-on module for acquisition, display and evaluation of "3D" chromatograms from PDA (DAD) detectors * Agilent…
  2. Main changes in the version 2.4 comparing to the version 2.3 * LOD, LOQ - the possibility to set the limits of detection and limits of quantification in the calibration window. The exceeding of the…
  3. # Fixed Bug: The control boards CB20/CB11 ignored the Max Change of Flow parameter # Fixed Bug: Agilent 5890/6890 digital acquisition was not functional # Fixed Bug: Agilent 5890/6890 problems in…
  4. # Fixed Bug: Skip vial passed to the next injection instead of to the next vial # Fixed Bug: The Result Table did not display any values in the Retention Index column # Fixed Bug: Agilent 6890 +…
  5. # Fixed Bug: Skip vial passed to the next injection instead of to the next vial # Fixed Bug: The Result Table did not display any values in the Retention Index column
  6. Main changes in the version 2.4.1 comparing to the version 2.4.0 * Agilent 1100 - Control Module for direct control of HPLC set over HPIB interfaces * EA module - Clarity for Elemental Analysis *…
  7. Main changes in the version 2.4.1 comparing to the version 2.4.0 * Automatic installation of Plug…
  8. * Agilent 1100 - Control Module for direct control of HPLC set over HPIB interfaces * EA module - Clarity for Elemental Analysis * Automatic installation of Plug…
  9. ------ Main changes in the version 2.4.1 comparing to the version 2.4.0 ----- * Automatic installation of Plug…
  10. * Control module for Shimadzu GC14C (simplified version of GC17A) # Fixed Bug: LPT hardware key was not functional in Windows NT # Fixed Bug: The calculation of RSD% in the SST module used the…
  11. # Fixed Bug: LPT hardware key was not functional in Windows NT # Fixed Bug: The calculation of RSD% in the SST module used the rounded values displayed in the SST table instead of the internal…
  12. # Fixed Bug: Possible crash under Win98 in case of chromatogram zooming or printing # Fixed Bug: Command Restore for Projects stored on CD was not functional # Fixed Bug: Non functional control…
  13. # Fixed Bug: Possible crash under Win98 in case of chromatogram zooming or printing # Fixed Bug: Command Restore for Projects stored on CD was not functional # Fixed Bug: Problem with starting of…
  14. * Agilent 1100: the lamp state can be now set in the method file # Fixed Bug: Export in the Dbf format overwrites the file without respect to the Append parameter # Fixed Bug: Potential error when…
  15. # Fixed Bug: Export in the Dbf format overwrites the file without respect to the Append parameter # Fixed Bug: Potential error when using the Restore – Project function # Fixed Bug: Incorrectly…
  16. *New: SST module: new parameter Amount [%] #Fixed Bug: AS Dani: the injection volume was not controlled by the Injection Volume column in the Sequence table #Fixed Bug: Invalid certificate for…
  17. #Fixed Bug: Invalid certificate for compatibility with MS Windows prevented automatic installation of the system drivers for INT7, U-PAD and CB20 during the installation of Clarity.
  18. *New: LC Control - the flow in the default LC method was changed to 0 ml/min to prevent unexpected start of pump. *New: The Setup Configuration window for Offline Instruments was modified to enable…
  19. #Fixed Bug: Mathematical Operation: when subtracting chromatograms with two signals the display of the first signal was suppressed.
  20. #Fixed Bug: GC control: Shimadzu GC17A - The Column Flow and Pressure obtained using the From GC in Method Setup - GC Control are now taken from GC Monitor instead of from method stored in device. #…
  21. #Fixed Bug: AS Control: HTA 300A - active sequence aborted randomly with "Vial not found." message
  22. #Fixed Bug: Export Data - the settings In fixed format were not stored #Fixed Bug: The ISTD calculation with ISTD amount set did calculate results for the Free calibration option (manual response…
  23. #Fixed Bug: GC Control: Agilent 68xx - the digital outputs dialog was not displayed in Clarity versions 2.4.4.134 and 2.5.3.72
  24. Main changes comparing to version 2.4.1 *New: The Run Again command is now available only when External Start setting in the Method Setup dialog is set to "Start-Restart". *New: Improved default…
  25. Main changes comparing to version 2.4.1 *New: New Clarity Extension: CE for Capillary Electrophoresis *New: Change to UNICODE character set. This change enables the localization of Clarity software…
  26. Main changes comparing to version 2.4.1 *New: Change to UNICODE character set. This change enables the localization of Clarity software to other languages including Chinese. As a consequence the…
  27. no changes in features, service release
  28. ------------- Main changes in the version 2.5 comparing to the version 2.4.4 ------------ *New: Hardware: For DataApex A/D boards the signal units can be configured in the Setup dialog accessible…
  29. ------------- Main changes in the version 2.5 comparing to the version 2.4.4 ------------ *New: Hardware: Support for higher sample rates introduced by the new A/D Converters INT9 and U-PAD2 (200…
  30. *New: Calibration: new option "Show recalibration points" was added into Graph Properties to display recalibration points in a calibration curve graph. *New: Chromatogram: new field “Chromatogram…
  31. *New: Calibration: new option "Show recalibration points" was added into Graph Properties to display recalibration points in a calibration curve graph. *New: Chromatogram: new field “Chromatogram…
  32. service release (not any feature changes)
  33. service release (not any feature changes)
  34. *New: AS Control - Spark Holland Triathlon - new tab with graphical tray display was added to Method Setup - AS Control dialog *New: Driver for MultiCOM, an USB-RS232 converter device, has is now…
  35. service release for compatibility with Clarity (not any feature changes)
  36. *New: LC Control: new control module for Hitachi - L-6200 pump - available for testing *New: LC Control: Shimadzu LC-10/20 system control - support for SPD-M20A - available for testing *New: LC…
  37. service release for compatibility with Clarity (not any feature changes)
  38. *New: DET: New control module for Softa ELSD detectors - available for testing *New: LC Control: New control modules for Young-Lin 9100 HPLC (developed by Young-LIN) *New: GC Control: New control…
  39. service release for compatibility with Clarity (not any feature changes)
  40. *New: Young Lin drivers were updated CswYL6100.dll 1.0.0.2, CswYL9120.dll 1.0.0.4 , CswYL9160.dll 1.0.0.3 *New: AS Control: Shimadzu SIL-20Axr/ACxr available for testing *New: LC Control: Shimadzu LC…
  41. service release for compatibility with Clarity (not any feature changes)
  42. ------------- Main changes in the version 2.7 comparing to the version 2.6 ------------ Control Modules: *New: Control modules Hitachi LaChrom Elite (L2100/2130 pump, L2200 autosampler, L2300 Column…
  43. ------------- Main changes in the version 2.7 comparing to the version 2.6 ------------ Installation: *New: New installer, it better controls the installation and uninstallation process of Clarity…
  44. ------------- Main changes in the version 2.8 comparing to the version 2.7 ------------ *New: Launch Manager - a utility for easy starting of Clarity with different configurations and user…
  45. ------------- Main changes in the version 2.8 comparing to the version 2.7 ------------ *New: Clarity Lite is compatible with Microsoft Windows 7. #Fixed Bug: Export Results: different format of…
  46. *New: Control LC: Young Lin updated drivers YL6100 version 2.0.0.5, YL9110, YL9120, YL9130, YL9160, YL9170, YL9180 version 2.0.0.3*New: Hardware: updated INT9 driver now supports 64 bit Windows*New:…
  47. *New: Hardware: updated INT9 driver now supports 64 bit Windows#Fixed Bug: Sequence - the  seq_import_append command line parameter worked incorrectly for certain columns#Fixed Bug: The…
  48. *New: Control: Updated drivers for  YL6100 GC  version 2.0.0.6,  YL9110 Pump.  YL9160 DAD, YL9170 RI   version 2.0.0.4#Fixed Bug: LC Control: HTA HT300A - nonfunctional Tray type detection.#Fixed Bug…
  49. --- service update - no changes in features ---
  50. #Fixed Bug: Clarity SDK could cause computer memory overwriting in control modules developed by external companies (bug introduced in version 2.8.3).