CLARITY RELEASE NOTES

  1. ----------------- CHANGES ------------------ * Command “Legacy Export” renamed to “Export Data” * Set of commands “Export Data in …” renamed to “Export Chromatogram in …” ----------------- FIXED…
  2. ----------------- CHANGES ------------------ * Beta version of the control module for Gilson 302-307 pumps * Beta version of the control module for LabAll series II, III, 1500, 150 pumps…
  3. ----------------- FIXED BUGS --------------- # An empty page was printed in case of printing a landscape oriented chromatogram itself # Error in Efficiency Calculation according to USP # In some…
  4. ----------------- FIXED BUGS --------------- # Incorrect printing of User´s Columns in Result Table # Missing error mesage when a LC pump was switch off during a run
  5. ----------------- FIXED BUGS --------------- # Fixed bug in ECOM4100 pump control module # Fixed bug: Missing items Inj. Volume and Amount in printed report
  6. ----------------- FIXED BUGS --------------- # Missing Response Base item in the Method file
  7. * The option to select units of the injection in the sequence has been discontinued * The units utilized in Amount and Inj. Volume are stated in the printout * The Total row from the Result Table…
  8. * The option to select units of the injection in the sequence has been discontinued * The units utilized in Amount and Inj. Volume are stated in the printout * The Total row from the Result Table…
  9. * The option to select units of the injection in the sequence has been discontinued * The units utilized in Amount and Inj. Volume are stated in the printout * The Total row from the Result Table…
  10. # Fixed Bug: Possible problem during U-PAD driver installation at some laptops # Fixed Bug: Possible problem caused by sleep mode # Fixed Bug: Disabled calibration points are printed like enabled (…
  11. * A default Sample Rate for U-PAD unit is 60 Hz and it is possible to change to 50 Hz in CSW32.INI file * A posibility to show following columns in Summary table: Weight, Area, Area%, Height,Height…
  12. * An Alpha version of Mettler balances control module # Fixed Bug: Missing flag "Modified" of Sample Table in case of using the command Save during Run
  13. * Summary Table now might consist of same columns as Result Table # Fixed Bug: In some cases the Summary Table wasn't consistent with Result table
  14. # Fixed Bug: Possible problem during print of Result Table containing User&#039s columns
  15. # Fixed Bug: Missing EAS32 PDF manuals # Fixed Bug: Mettler balances control module # Fixed Bug: A possible crash after repeated using "Save as Picture to Clipboard" command
  16. # Fixed Bug: A possible problem using an original INT7 method with U-PAD at 60Hz
  17. # Fixed Bug: A possible problem using an original INT7 method with U-PAD at 60Hz
  18. ----------------- CHANGES ------------------ * Command Export renamed to Export Legacy ----------------- FIXED BUGS --------------- # Fixed Bug: Non functional selection of name and directory in…
  19. ----------------- FIXED BUGS --------------- # Fixed Bug: Improper detection of input range of Import data in text format # Fixed Bug: Direct control of AS in sequence
  20. ----------------- CHANGES ------------------ * Command "Legacy Export" renamed to "Export Data" * Set of commands "Export Data in …" renamed to "Export Chromatogram in …" * Beta version of the…
  21. ----------------- CHANGES ------------------ * Beta version of the control module for Gilson 302-307 pumps * Beta version of the control module for LabAll series II, III, 1500, 150 pumps * The flow…
  22. # Missing Response Base item in the Method file # Fixed bug in ECOM4100 pump control module # Fixed bug: Missing items Inj. Volume and Amount in printed report # Incorrect printing of User´s…
  23. ----------------- FIXED BUGS --------------- *The status of sequence is not reset automatically
  24. ----------------- CHANGES ------------------ * Control module for Sartorius balances CP, GC and GP series has been finished * Useless columns (Moments,Dead time,...) from Export Data command have…
  25. * The Balance dialogue box has been extended for button Close. In case of weighting of series samples this button doesn´t clear already measured weights. # Fixed bug: A problem with decimal point…
  26. * The Balance dialogue box has been extended for button Close. In case of weighting of series samples this button doesn´t clear already measured weights # Fixed bug: A problem of decimal point…
  27. ----------------- FIXED BUGS --------------- # Fixed Bug: Possible crash caused by command Set Model # Fixed Bug: Possible crash caused by command Save As Chromatogram or Calibration
  28. ----------------- FIXED BUGS --------------- # Fixed Bug: Possible crash caused by command Set Model # Fixed Bug: Possible crash caused by command Save As Chromatogram or Calibration
  29. ----------------- CHANGES ------------------ * To run "Noname" sequence table is not allowed ----------------- FIXED BUGS --------------- * Impossible to overwrite already existing file with…
  30. ----------------- CHANGES ------------------ * To run "Noname" sequence table is not allowed ----------------- FIXED BUGS --------------- * Impossible to overwrite already existing file with…
  31. --- Changes in the version 2.2. comparing to the version 2.1 --- Changes in the Sequence: - Line control in the Sequence table - Importing Sequence Table in text format - The possibility to repeat…
  32. --- Changes in the version 2.2. comparing to the version 2.1 --- Changes in the Sequence: - Line control in the Sequence table - The possibility to repeat injections in a sequence - Change in…
  33. # Fixed Bug: Minor amendments in GC17A Control Module # Fixed Bug: Minor amendments in HP6890 Control Module # Fixed Bug: Tendency to crash when using the Edit menu in the Summary Table dialog #…
  34. # Fixed Bug: Minor amendments in CTC A200S Control Module * Control module for HTA AS300A was extended to HTA AS300L model * New variables in Run item (Postrun and Batch commands): %f =…
  35. * New variables in Run item (Postrun and Batch commands): %f = Chromatogram filename, %e = Export filename * AIA export: level C2 changed to C1 # Fixed Bug: Possible problem during U-PAD driver…
  36. ------------- Main changes in the version 2.3 comparing to the version 2.2 ------------ * GPC module * Calibration – Calibration points history * Calibration – Calibration table displays…
  37. ------------------- Changes in the version 2.3 comparing to the version 2.2 ---------------------- * Calibration – Calibration points history * Calibration – Calibration table displays deviations…
  38. ------------- Main changes in the version 2.3 comparing to the version 2.2 ------------ * GPC module * Calibration – Calibration points history * Calibration – Calibration table displays…
  39. # Fixed Bug: Accidental delay (0-1.2s) between the channels of U-PAD converter in case of synchronous acquisition # Fixed Bug: Inaccuracy in the printing of the calibration curve when using the "Use…
  40. * SST limits can now be optionally applied not only to a mean of values but also to individual values * SST Results in multi-detector chromatograms can be calculated for any selected signal * New…
  41. * Knauer Smartline S 1000 configuration file for Universal HPLC Control Module (= LC UNI) # Fixed Bug: Minor amendments in LC UNI
  42. * New profiles for Universal Pump Control Module: LabAlliance series III, prep 100 and prep 1500, Ecom 4100, Beta 10 and Beta 50 * The LC Monitor window distinguishes between expected values (…
  43. # Fixed Bug: The Signal in Data Acquisition window did not display after positive exceeding the Range (Over) # Fixed Bug: At certain conditions the values indicated in the status bar of Data…
  44. * New profiles for Universal Pump Control Module: LabAlliance series III, prep 100 and prep 1500, Ecom 4100, Beta 10 and Beta 50 * The LC Monitor window distinguishes between expected values (…
  45. # Fixed Bug: The Signal in Data Acquisition window did not display after positive exceeding the Range (Over) # Fixed Bug: At certain conditions the values indicated in the status bar of Data…
  46. # Fixed Bug: Minor amendments in HP6890 Control Module # Fixed Bug: Minor amendments in Spark Endurance Module
  47. # Fixed Bug: Minor amendments in HTA300L Control Module
  48. # Fixed Bug: Chance of premature termination of the station during longtime sessions (over 7 days) # Fixed Bug: Minor improvements in the HTA300L module # Fixed Bug: Chromatograms measured in the…
  49. # Fixed Bug: GC17A – The "From GC" command did not transfer the flow on the column correctly # Fixed Bug: Agilent 6890 – Incorrectly displayed curves for high levels of the signal # Fixed Bug:…
  50. Main changes in the version 2.4 comparing to the version 2.3 * PDA module - integrated add-on module for acquisition, display and evaluation of "3D" chromatograms from PDA (DAD) detectors *…