Search
Displaying 2201 - 2250 of 3206
GUIDES & DOCUMENTATION
- It is possible to import sequence that has been stored in a text file. Values have to be in delimited format and separated by an arbitrary delimiter. Import of the sequence is one of the functions…
- This topic describes how to improve Match probability with library compounds. Restrict m/z Range Serves for narrowing the m/z range to be searched. In the case, you know approx. m/z you are…
- This topic describes how to improve Match probability with library compounds. Restrict m/z Range Serves for narrowing the m/z range to be searched. In the case, you know approx. m/z you are…
- Standard addition is a quantification approach (similar to ESTD or ISTD) useful in case the sample matrix is complex and when it influences responses of analytes. By spiking samples with a series of…
- Topics covering installation of Clarity software, Colibrick, Multicom, etc. Also the connection between Clarity and chromatograph is explained.
- This chapter will guide you through the installation process of Clarity and the initial setup of connected devices. Caution: Do not connect any devices, such as Colibrick, before installing Clarity!
- The CE Extension is activated by entering an appropriate user code during the installation of Clarity or later using the Help - User Code… command from the Clarity main window. To enable the CE…
- The DHA Extension is activated by entering an appropriate user code during the installation of Clarity or later using the Help - User Code… command from the Clarity main window. To enable the DHA…
- The EA Extension is activated by entering an appropriate user code during the installation of Clarity or later using the Help - User Code… command from the Clarity main window. To enable the EA…
- The GCxGC Extension is activated by entering an appropriate user code during the installation of Clarity or later using the Help - User Code… command from the Clarity main window. To enable the…
- The GPC Extension is activated by entering an appropriate user code during the installation of Clarity or later using the Help - User Code… command from the Clarity main window. To enable the GPC…
- The MS Extension is activated by entering an appropriate user code during the installation of Clarity or later using the Help - User Code… command from the Clarity main window. To enable the CE…
- The MS-MS Extension is enabled by appropriate user code entered during installation or later by using the Help - User Code command from the Clarity main window. To switch an Instrument to a mode…
- The NGA Extension is activated by entering an appropriate user code during the installation of Clarity or later using the Help - User Code… command from the Clarity main window. To enable the NGA…
- The PDA Extension functions are activated by entering an appropriate user code during the installation of Clarity or later using the Help - User Code command from the Clarity main window. To enable…
- Caution: Install Clarity before connecting the Colibrick to the USB port. Drivers will be installed automatically during the installation of Clarity. Install Clarity from the provided medium or…
- One of the requirements for ensuring the reliability of generated results is the validation of all instrumentation and procedures that are used to acquire data. Levels of Qualification For…
- The Installation Qualification (IQ) is a procedure that confirms the successful installation of the software and verifies the correctness of the file versions. IQ is an integral part of the Clarity…
- The Dual Chromatogram Mode is already available in the installed Clarity. To enable the Dual Chromatogram Mode on an Instrument, set a supported Instrument Type ⓐ (e.g., GC) in the Instrument Type…
- Currently supplied RkNDUSB HW keys use the HID (Human interface device) technology and do not require any drivers. For old RkUSB keys the drivers will be installed automatically during the…
- When Windows user accounts are already present on the PC it is recommended to install Clarity from a user account, that will work with it, using the Run as administrator option. When no Windows user…
- These are the basic steps you have to follow for the First installation of Clarity. First installation of the software (since version 9.0) Install the software BEFORE connecting any hardware.…
- Colibrick is an external 24-bit A/D converter designed for acquisition of data from any chromatograph. It uses the USB communication channel and it is powered from the PC. First install Clarity…
- MultiCOM is a USB to RS232 converter developed for controlling via the RS232 serial interface. It is connected to the PC via the USB port and has 6 serial 9-pin ports. It also has a free USB port…
- The Instrument window is the central interface for chromatogram measurement and evaluation. To open it, select Login to Instrument from the Instruments submenu or click the corresponding icon in the…
- Instrument This is a sub-menu of commands for setting up projects, working with system files and exiting an Instrument. Project… Selects project directory. Archive… Backs up files…
- Clarity is prepared for development of control modules for CE instruments. CE Instrument Type was added to the System Configuration dialog and new Inlet Vial (InV) and Outlet Vial (OutV) columns are…
- Instrument Directories for Projects The Instrument Directories for Projects dialog allows users to change the location of Project directories for the instrument and the Audit Trail directory from…
- During measurement, in the Instrument window, the Chromatogram, Sample, and Sample ID rows are divided in half to display both the Front and the Back position contents. If the content for both…
- Analysis Procedure: Step 1 -> Step 2 -> Step 3 -> Step 4 Start the Clarity station. The main window will appear. Open Instrument which is prepared to test the Single Analysis. In Clarity…
- In the EA Mode the Instrument window has different appearance. EA Instrument window The Single Analysis and Sequence icons in the Scheme of Data Processing have been replaced by a single EA…
- When you set an instrument to GPC in the System Configuration dialog, the instrument will open in GPC Mode. This mode configures the instrument to display GPC-type results, such as molecular weight…
- Instruments A submenu with commands for access to individual instruments. Items in the menu are displayed dynamically, depending on how many instruments are configured, whether any user is logged on…
- Integration Sets the integration parameters. When invoked by the menu command or by the icon, the Method Setup - Integration dialog will be opened. Method Setup - Integration Select Detector…
- Integration Menu for adjustment of integration parameters. All commands can also be invoked using icons from the Integration toolbar. All integration parameters are executed as a part of the…
- Integration Invoking this command switches the results panel of the Chromatogram window to the Integration tab, which contains the selector of the integration algorithm and the Integration Table.…
- In MS Extension, two types of signals can be integrated: Quantification Signals and Result Table Signal. Result Table Signal Result Table Signal serves for filling the Result Table with peaks…
- In MS-MS Extension, two types of signals can be integrated: Quantification Signals and Result Table Signal. Result Table Signal Result Table Signal serves for filling the Result Table with peaks…
- Compression Factor where the summation is taken over all N components of the mixture and: Z(t2,p2) is the compression factor at metering temperature t2 and metering pressure p2 p0 is the…
- K & Alpha The K & Alpha dialog can be opened using the Load K & Alpha button in the Single Analysis dialog or using the Sequence - Select K Alpha... command ( icon) from the Sequence…
- Keep in mind that: The calibration curve and equation will not be displayed, if the equation could not be constructed using all the points marked as used. Please check that you have entered…
- The CE Extension adds the following features to the Clarity station: CE-specific terminology evaluation by time corrected area peak identification by peak start or end (as an addition to the peak…
- The EA Extension brings the following features to the Clarity station: Sequence mode only - since the Elemental analyzers are commonly used for large series of samples, the single analysis mode is…
- The GPC Extension brings the following features to the Clarity station: Evaluation - the same chromatograms can be evaluated both in standard and GPC mode. GPC Integration - separate integration…
- The MS Extension brings the following features to the Clarity station: MS Chromatogram window - standard Clarity Chromatogram window was modified to display the spectral information too. The graph…
- The MS-MS Extension brings the following features to the Clarity station: MS Chromatogram window - standard Clarity Chromatogram window was modified to display the spectral information too. The…
- The PDA Extension brings the following features to the Clarity station: Possibility to handle PDA data: Clarity can acquire and work with PDA data from various PDA detectors. Import/Export Data:…
- Lab. Footer Tabs: Page Setup - Lab. Header - Report Header - Method - Calibration - Chromatogram - Results - Sequence - SST - MS - Audit & Signatures - PDA - NGA - DHA - Lab. Footer Specifies…
- Lab. Header Tabs: Page Setup - Lab. Header - Report Header - Method - Calibration - Chromatogram - Results - Sequence - SST - MS - Audit & Signatures - PDA - NGA - DHA - Lab. Footer Specifies…
- This dialog is displayed in case the Clarity is set to a language which is not available for your licence (User Code). Please, contact DataApex to consult the languages availability. Language…