  1. INT7 is an internal 24-bit A/D converter board that measures the voltages of detectors. It contains up to 4 data-acquisition channels on one board (one and two channel versions are also available).…
  2. INT9 is an internal 24-bit A/D converter card that measures the voltages of detectors. It contains up to four data-acquisition channels on one board (one and two channel versions are also available…
  3. The Interlab MAESTRO Control module allows for direct control of Interlab MAESTRO HPLC System. The control is performed via USB. The control module allows the digital acquisition of the detector…
  4. The control module enables direct control of the Interlab Omega UV-VIS and Omega FLD detector over USB. The user can easily create the detector control method from the Method Setup - Acquisition…
  5. The JAI RI-700II Control module allows for direct control of the JAI RI-700II detectors. The control is performed using serial communication. The control module allows the digital acquisition of one…
  6. The Jasco FP-4020/4025 control module allows for direct control of the Jasco FP-4020 and FP-4025 fluorescence detectors. The control is performed via a standard PC serial port using a specified…
  7. The cable can be customized (p/n KBSP) or extended (p/n KP). Detailed cable description can be found in an A/D Manual or in the Getting Started Manual. Clarity getting started guide Hardware…
  8. The cable can be customized (p/n KBSP) or extended (p/n KP). Detailed cable description can be found in an A/D Manual or in the Getting Started Manual. Clarity getting started guide Hardware…
  9. The cable can be customized (p/n KBSP) or extended (p/n KP). Detailed cable description can be found in an A/D Manual or in Getting Started Manual (manuals available in the download section). The…
  10. The cable can be customized (p/n KBSP) or extended (p/n KP). Detailed cable description can be found in an A/D Manual or in the Getting Started Manual. Clarity getting started guide Hardware…
  11. This item is to be ordered together with a new cable (a cable can be a part of A/D converter). Each standard cable for our A/D converter can be modified for a combination of up to 4 TTL inputs and up…
  12. DataApex started a close cooperation with Knauer and Young In Chromass (formerly YoungLin) companies. We are happy that these partnerships have lasted until now.
  13. The UNI Ruby Control Module with the Kontron 432 profile allows for the direct control of the Kontron 432 detector over serial line. Direct control means that the detector method parameters can be…
  14. The UNI Ruby Control Module with the Kontron 360/560 or Kontron 460/465 profile allows for the direct control of the Kontron 360, 460, 465 and 560 autosamplers. The control module enables direct…
  15. This item is to be ordered together with a new cable (a cable can be a part of A/D converter).
  16. The LC control license unlocks all liquid chromatography control modules available in Clarity. LC control license allows direct control of LC pumps and their gradients, a broad variety of LC…
  17. How to calibrate results in an already measured or newly created chromatogram using your calibration file.
  18. The Markes BenchTOF Control module allows for direct control of the Markes (Almsco) BenchTOF-dx GC-MS detector. The control is performed via LAN. The control module allows the digital acquisition of…
  19. We provide you with a Brand Identity Guide that serves as a comprehensive document that outlines the visual elements that will guide you on how to use the Clarity and DataApex brand names with your…
  20. DataApex Brand Identity Guide, logos and other graphic elements that help you to prepare your marketing materials.
  21. Our portfolio of Extensions has been widened by MS Extension and complemented our first spectral extension - PDA. It allows the measuring and processing of data that has been acquired from selected…
  22. The Mettler Toledo control module enables direct control of the analytical balance over serial line. Direct control means that the weight can be automatically obtained from the Clarity environment…
  23. The Microsaic 4500 MiD Control module allows for direct control of the Microsaic 4000 and 4500 MiD LC-MS detectors including the MiDas module. The control is performed via LAN. The control module…
  24. Not only DataApex but also our portfolio of controlled instruments is still growing. Recently, Clarity has hit 1000 controlled instruments. More to come in the future.
  25. In 2012, DataApex acquired a new office space at Petržílkova. Since then you can meet us here on our trainings.
  26. Clarity can automatically export a chromatogram after analysis or when the reprocessing of the chromatogram is finished. This macro will automatically load the exported chromatogram to MS Excel,…
  27. The Clarity MS Extension is a tool that is used for processing data that has been acquired from selected Mass Spectrometry detectors. Spectral data, together with chromatograms, add a third…
  28. MultiCOM allows the connection of multiple devices controlled via a COM line (RS232). Many controlled devices are connected to a PC via serial cables, which require a standard 9-pin (plug) connector…
  29. Switching between multiple Clarity windows using keyboard shortcuts and using the Clarity Switch.
  30. How to zoom a part of the graph and turn on the preview graph. How to move along the x/y-axes and change the range of the y-axis.
  31. Net-PAD is an external high-resolution A/D converter for chromatography data acquisition. Net-PAD communicates with a PC over Ethernet through a TCP/IP protocol. Clarity Chromatography Software,…
  32. NGA Extension is a software module for natural gas and liquefied petroleum gas data processing. You no longer need an external tool for gas properties calculations since Clarity contains the complete…
  33. Two tips on how to quickly open measured chromatograms.
  34. The OPT-USB adapter translates signals between an optical cable and a USB. The converter software emulates a COM port in the PC, so that it can also be used as an optical to RS232 converter. It can…
  35. The PDA Extension is an optional Extension that is used for processing data that has been acquired from selected photo diode array detectors. Spectral data, together with chromatograms, add a third…
  36. This video shows the standard integration workflow in Clarity, step by step. Each step will be explained in detail in separate videos.
  37. Clarity can communicate with the HPLC system using the RC.net driver. Users can easily create the instrument control method from various tabs in the Method Setup dialog, corresponding to the system…
  38. Clarity can communicate with the detector through Syngistix software installed on the same PC. Users can easily create the detector control method from the Method Setup - Acquisition tab. All of the…
  39. Overview of post run actions in Clarity.
  40. Step-by-step guide on how to print from the sequence with an explanation of basic print principles in Clarity.
  41. DataApex Ltd.Lety 24 252 29 DobřichoviceCzech RepublicTel: +420 251 013 400To receive free disclosure about any of your personal information, or if you have questions or comments concerning our…
  42. How to recalibrate a level in the calibration. The video also includes where to find details of the calibration point and how to omit it from the calibration.
  43. How to recalibrate or add a peak to the existing calibration.
  44. The Recipe EC6000 Control module allows for direct control of the Recipe EC6000 Electrochemical detector. The control module allows the digital acquisition of one signal. The user can easily create…
  45. When importing chromatograms exported from Chemstation to Clarity we will need to name the filenames according to the chromatogram name indicated in the parent folder and move the chromatograms to a…
  46. The UNI Ruby Control Module with the Rheodyne LabPro valves profile allows for the direct control of the Rheodyne LabPro series valves. Control is realized via a standard PC serial port using a…
  47. The Rheodyne Valves Control Module enables direct control of the Rheodyne MX II series valves over USB line and Titan series valves over RS232 line. Direct control means that the valves can be…
  48. The Sartorius control module enables direct control of the analytical balance over serial line. Direct control means that the weight can be automatically obtained from the Clarity environment and…
  49. The Schambeck RI2012 Control module allows for direct control of the Schambeck RI2010, RI2012, S 2020 and S 2030 detectors. It is performed using the UNI Ruby control module using the…