Search

Displaying 1151 - 1200 of 3251

PRODUCTS PAGES & DOCUMENTS

  1. The UNI Ruby Control Module with the Advantec CHF122SC profile allows for the direct control of the Advantec CHF122SC fraction collector and its OEM versions, such as Waters Fraction Collector II.…
  2. The Advion Expression CMS Control module allows for direct control of the Advion Expression CMS LC-MS detector. The control is performed via USB. The control module allows the digital acquisition of…
  3. The Agilent 1100/1200 Control module enables the direct control of the Agilent 1100 HPLC system and Agilent 1200 HPLC system over GPIB or LAN. Direct control means that the HPLC system can be…
  4. The Agilent 5890 GC driver can control Agilent (formerly HP) 5890A, 5890 Series II and 4890D chromatographs. The control is performed over HPIB interface card. The boards supplied by Agilent (see the…
  5. The Agilent 68xx GC driver can control Agilent 6820, 6850, 6850 II, 6890, 6890N, and 6890+ GC chromatographs. Clarity can communicate with the GC through HPIB/RS232 interface or using the LAN…
  6. The Agilent 7673 Control module enables direct control of the Agilent automatic liquid sampler (ALS) for GC. It provides a complete control of the Agilent 7673A, 7673 II and 7683 ALS. The control of…
  7. Clarity can communicate with the GC using the LAN connection. The module can control also the Agilent 7683 or 7693 Autosampler connected through the GC. AS Control (p/n A26) has to be purchased to…
  8. ICF provides a unified driver environment and enables the use of Agilent-developed RC.NET drivers for Agilent instruments in any software package that supports ICF interface. It also allows the use…
  9. Direct control of Agilent gas chromatographs (listed in the below table) using the Agilent ICF (Instrument Control Framework) tools developed by the Agilent company. The Clarity Chromatography…
  10. Direct control of Agilent 1100, 1120, 1200, 1220, 1260 Infinity, 1260 Infinity II/III and 1290 Infinity II/III HPLC components using the Agilent ICF (Instrument Control Framework) tools developed by…
  11. Browse all of the available Clarity Tips & Tricks videos in this playlist.
  12. The Alltech/Grace 3300 ELSD Control module allows for direct control of the Alltech/Grace 3300 ELSD (evaporative light-scattering) detector. The control module allows the digital acquisition on one…
  13. The Analytical Balance control is automatically unlocked in Clarity EA software. It provides direct input of weight into the sequence table. The functions specific to selected analytical balance can…
  14. The Antec DECADE Elite Control module allows for direct control of the Antec DECADE Elite electrochemical detector. It allows the digital acquisition from all detector cells, use of the digital…
  15. The Antec DECADE II Control module allows for direct control of the Antec DECADE II, DECADE II SDC, DECADE II MD and ROXY Potentiostat electrochemical detectors. It allows the digital acquisition…
  16. DataApex company was founded in 1991. The idea came from a family request to replace an old integrator. Six months later, the Apex software and our own first A/D converter were born.
  17. The software runs in MS-DOS and consists of an A/D converter board for PCs and the corresponding software.Apex can be connected to practically any gas or liquid chromatograph and operates one or two…
  18. In consideration of the many and variant operating systems, chromatographic stations and hardware available for data acquisition and in use today we offer the following summary table of possible Apex…
  19. Brief overview of the parameters:The whole software package was distributed on a single 1.44 MB floppy diskThe system was easily running on Intel 286 computerIt was possible to use Apex on PC without…
  20. The AS control license unlocks all autosampler control modules (LC, GC, and headspace autosamplers) available in Clarity. It allows direct control of injection routines, such as injection and washing…
  21. The UNI Ruby Control Module with the ASI pumps profile allows for the direct control of the ASI 500, 501, and 520 pumps. The control module enables direct control of the instrument over a serial line…
  22. Application examples of Clarity software for analytical and small scale preparative separation using multivendor analytical and preparative HPLC components.
  23. The UNI Ruby Control Module with the Valco valve AS profile allows for the direct control of the VICI Valco multiposition valves when they are used as autosampler. The control module enables direct…
  24. The Axcend Focus LC Control module allows for direct control of the HPLC system over LAN interface.The Axcend Focus LC is a hand-portable UV-Absorption-based capillary HPLC that runs on AC or DC…
  25. The General Purpose Fraction Collector Control Module enables the control of the Bio-Rad BioFrac fraction collector by the use of TTL outputs. To be able to control the fraction collection, it is…
  26. The Bischoff 2250 Control module allows for direct control of the Bischoff 2250 LC pumps. The high pressure gradient is created from up to four individual gradient components where each component is…
  27. Distributing Clarity productsOEM CooperationsSDK for Drivers' developmentAgilent Instrument Control Framework (Agilent ICF)
  28. A brief introductory overview of the Clarity Calibration window.
  29. The CB11 card is designed for controlling LC pumps (that can be steered by frequency or voltage) by means of the Clarity chromatography software.The internal ISA control board CB11 contains:four 14-…
  30. The CB20 card is designed for controlling LC pumps (that can be steered by frequency or voltage) using Clarity chromatography software. It contains four 16-bit D/A converters and four 28-bit…
  31. The CE Extension activates the CE mode in Clarity environment and can be activated on any Clarity Instrument. CE Extension is compatible also with Clarity Offline software. CE module provides…
  32. The CETAC ASX-8000 control module enables direct control of the ASX-8000 autosampler. The control is performed over USB. Direct control means that the autosampler can be completely controlled from…
  33. We have been developing chromatography software for more than 30 years, and Clarity is our third generation of this product. It is software for data collection, processing, and instrument control.…
  34. The UNI Ruby Control Module with the Chromophor pumps profile allows for the direct control of the Chromophor Chromopeak 2010 pump. The control module enables direct control of the instrument over…
  35. Clarity can communicate with the HPLC system using several separate control modules. Users can easily create the instrument control method from various tabs in the Method Setup dialog, corresponding…
  36. Browse all the available videos covering the Batch topic in this playlist.
  37. Overview of the dialog where you can process multiple chromatograms at once - update the Integration, Calibration, perform Post Run Options, etc.
  38. Browse all the available videos covering the Calculation in this playlist.
  39. Browse all the available videos covering the Calibration topic in this playlist.
  40. Optional control modules for over 1000 instruments provide integrated digital control of selected GCs, LCs, pumps, detectors, autosamplers, etc. Extensions provide functions for specific separation…
  41. 中文版本色谱工作站完全中文本地化。超过1000多种仪器型号控制仪器控制模块包括气相色谱仪、液相色谱输液泵、检测器、自动进样器等等。点击获取详细清单或下载具体介绍。扩展模块扩展模块包括PDA二极管阵列检测器、GPC凝胶色谱、质谱仪和SST系统适应性测试。OEM仪器控制开发我们可以根据您的特殊要求,提供软件定制开发。详情请浏览OEM页面。免费演示软件请点击下载Clarity演示软件,…
  42. Please see the tables below before installing or upgrading to a new version of Clarity. The Computer requirements table lists the computer hardware requirements. The System compatibility table…
  43. Clarity configurations examples Up to 4 chromatography systems can be configured on one PC. The following figures display typical configurations of Clarity chromatography software. Each…
  44. There is a high probability that everything will work right, but we can't guarantee it with as much certainty as for controls with Ready state. It is possible that some special configurations and…