Clarity release notes

  • Clarity
  • Clarity Lite
  •  

Changes in version 2.4.4.83 (9.11.2006)

Main changes comparing to version 2.4.1

*New: Change to UNICODE character set. This change enables the localization of Clarity software to other languages including Chinese. As a consequence the system files (clarity.cfg, clarity.psw, all *.dsk files) are not backward compatible with previous versions.

*New: Clarity EVAL solution was renamed to Clarity Offline to prevent confusion with the Demo version.
*New: The Windows98/Me are no longer supported in Clarity version 2.4.2 and higher. Older versions (2.3.0 and 2.4.1) are still available for downloads.

*New: Graph Properties: Peak Area Coloring - The area of peaks can be colored based on the color specified in calibration, and/or it can be used to highlight selected peak(s)

*New: Method Setup window tabs were reorganized:
- Event table is now common to all devices on the same Clarity Instrument and is displayed at special tab.
- Event Table was moved from Method Setup - Acquisition to new Method Setup - Event Table tab
- External Start options were moved from Method Setup - Acquisition to Method Setup - Measurement tab

*New: Automatic recalibration at selected level is possible also in Single Analysis

*New: Tables - new Fill Down function (CTRL+F) will copy content of current cell to all cells bellow it. In Start Vial column in Sequence table it will automatically increment values.
*New: New Common columns in the Chromatogram - Summary table
*New: In the single detector operation Clarity now does not use color in the header of calibration tables to indicate the columns that are detector specific.
*New: Chromatogram - Results table: new columns "Start time" and "Stop Time" display retention time of peak start/end. Hidden by default
*New: New "Compound Name" column in the Chromatogram - Performance table
*New: Tables: automatic switching of the number format to exponential was suppressed.
*New: The peak area coloring is indicated in the row header of the Result Table (Chromatogram window).


*New: The Import Chromatogram dialog can now import multi-detector chromatograms from TXT format.
*New: Possibility to export User Columns from the Results Table.
*New: Export Data dialog - new checkbox "Summary" enables to export the Summary table.
*New: The Summary Table is exported "as on screen" instead of fixed format
*New: Export Chromatogram window contains new "Character Encoding" listbox.
*New: Export Data dialog customizable setting of decimal separator.
*New: Export Data to DBF format - repaired incompatibilities with DB III+ format specification.

Changes in version 2.4.4.82 (9.11.2006)

Main changes comparing to version 2.4.1

*New: The Run Again command is now available only when External Start setting in the Method Setup dialog is set to "Start-Restart".
*New: Improved default chromatogram file naming template will provide unique filenames in every circumstance.
*New: Possibility to see the name of template method used during chromatogram acquisition in the Chromatogram window.
*New: Calibration Options dialog - Retention Index now has new option: Use Unretained Time.
*New: The Noise value is now displayed more precisely (with tenths of µV)
*New: The Injection Volumes can be now set in 1/1000 ml. (However it is still possible to switch to µl)
*New: The new sequence is set to Active by default (according to the setting in template.seq in Common subfolder)

*New: New command line parameter "stop" for stopping single analysis or sequence in progress.
*New: New command line parameter export_run_time.

*New: Better specified error messages related to trial period use.
*New: The examples from the default installed projects (WORKX) were moved to the new projects (DEMOX).
*New: Clarity SW folder reorganization - Clarity LC UNI driver profiles moved from CTRLLC to UTILS.
*New: The documentation files installed with Clarity (DOC PDF folder) were unified and separated into corresponding subfolders.
*New: The installation utility will detect previous installation of Clarity and offer to install into the same folder.
*New: Installation of the free Adobe Acrobat Reader was included in the CD version of Clarity.

#Fixed Bug: Printing from the sequence now prints only chromatograms opened in the Chromatogram window.
#Fixed Bug: Printing of chromatogram did not always create a record in the Chromatogram history. Now it will even when the chromatogram was not changed.
#Fixed Bug: The sequence ignored changes made in the Current value field in the Sequence Options dialog when the sequence was paused.
#Fixed Bug: At certain situations the method was incorrectly marked as changed when closing the Method Setup dialog.
#Fixed Bug: Paste Insert command inserted new line before the row with focused cell instead of before the selected line.
#Fixed Bug: The formula for calculation of Standard Deviation in User Columns was changed to more common type.
#Fixed Bug: The Run button in Data Acquisition window was inactive during single run.
#Fixed Bug: The Paused and Idle Sequence statuses were incorrectly turned to Waiting when the related template method was edited.
#Fixed Bug: Calibration automatic, the Add Single Peak command created separate level for each peak created from the same chromatogram.
#Fixed Bug: The time axis in the Data Export were exported with 3 decimal places precision only, now it is 5 decimal places.
#Fixed Bug: The values pasted to the tables in the Calibration window were rounded to 3 decimal places regardless the global setting.
#Fixed Bug: The printout of summary table was not entirely WYSIWYG.
#Fixed Bug: Improvements in Clarity command line support.

Changes in version 2.4.4.105 (5.1.2007)

#Fixed Bug: Mathematical Operation: when subtracting chromatograms with two signals the display of the first signal was suppressed.
 