Changes in version 2.3.0.174 (4.11.2004)

# Fixed Bug: The Signal in Data Acquisition window did not display after positive exceeding the Range (Over)

# Fixed Bug: At certain conditions the values indicated in the status bar of Data Acquisition window were not updated

# Fixed Bug: Updated UPAD driver (necessary for Windows XP with Service Pack 2)

# Fixed Bug: Minor amendments in printing

# Fixed Bug: It was not possible to set external start after disabling the first detector in the Method Setup dialog

# Fixed Bug: Systemizing the behavior of the Event Table for digital output and external program

# Fixed Bug: Corrected malfunction of Save As Chromatogram command when using the Subtract Chromatogram feature

# Fixed Bug: Minor amendments of mathematical operations with chromatograms

Changes in version 2.3.0.162 (31.8.2004)

# Fixed Bug: Accidental delay (0-1.2s) between the channels of U-PAD converter in case of synchronous acquisition

# Fixed Bug: Inaccuracy in the printing of the calibration curve when using the "Use User Options" checkbox

# Fixed Bug: Incorrect results in ISTD Calculation when the calibration curve cannot be constructed

# Fixed Bug: The delay on the chromatogram's Time Axis (~20-200ms depending on the Sample Rate) has been compensated.

# Fixed Bug: Minor amendments in Event table

Changes in version 2.3.0.146 (28.6.2004)


------------------- Changes in the version 2.3 comparing to the version 2.2 ----------------------

* Calibration – Calibration points history

* Calibration – Calibration table displays deviations of all calibration points

* Calibration – Calibration displays a calibration curve residuum calculation

* Print – Images ( picture, logo) in report header

* Print – Option for printing an active signal (detector) or all signals

* Print – Option for Black and White print

* Print – Option for signals ( chromatograms) separate printing in one protocol

* Event table – Option for an external program Run

* Event table – Option for Puls Output level

* Summary table – Extended option for Summary table layout

* Summary Table – Displays the same colums as displayed in Results table

* Acquisition – Option for data acquisition from only selected detectors directy from Method

* Acquisition – New variable for automated chromatogram naming %Q –Sample, %q - Sample ID

* Acquisition – Option for actual noise level in Data Acquisition Window

* Chromatogram – Move and Scale commands applied to all signal from multidetector chromatograms using Shift key at a time

---------------------------------------------------------------------------------------------------
 