DOWNLOADS
- Zebrick D/A and D/f converter (Documentation - Manuals)
FAQ
- The "No Data received for 10 sec" or "No data from Acquisition..." messages mean what they say, no data were received from a detector or A/D converter (Colibrick, etc.) for a certain time.…
- Yes, Clarity can be connected to any LIMS by importing/exporting text files. Results can be exported in various formats to the LIMS, and the sample info can be imported from a TXT file into Clarity…
- Yes, it can. However, the philosophy of use is slightly different. The peak areas of a selected group of peaks are summed, and the group can be named and calibrated as a single compound. Please refer…
- There may be multiple different reasons. Please check the detailed status in the Instrument window and Device Monitor.Waiting for Injection - indicates parameters for injection were sent to the…
- Dani Master GC In case your Master GC has an older firmware that supports an older version of Clarity than you have installed it is possible to use older drivers in newer Clarity (up to 8.1).…
- Yes, you will need to purchase an upgrade if the major version of the software has changed and if you are not eligible for a free upgrade as you have exceeded the one-year free software upgrade…
- If you have bought an extension or control module license, you will get a new user code for the latest SW version and have to use the version compatible with the user code (if you have it, there is…
- Bar code scanner support is implemented within a few autosampler control modules (Spark Integrity, HTA HT4000, …). The read bar code will be available as the %f variable for use in SampleID, Sample,…
- Clarity is a 32-bit process, which means it can use the max of 2GB RAM, but if you use more than one demanding instrument, it can still be beneficial to have 8 GB RAM, so the PC has enough RAM left…
- Most chromatography systems use a proprietary data format (the main reason is the belief that it ensures data integrity for GLP-related requirements). To open and process such chromatograms in…
- Multiposition valves are frequently used as a simple fraction collector for preparative purposes.Knauer provides dedicated control modules for multiposition valve-based fraction collectors…
- An upgrade to the new major Clarity version (change in the first number before the dot) is paid and requires a new user code. Please refer to your price list under p/n C500 (C400/C591). All minor…
- The peak detection algorithm used in FC-GP can be explained using the figure below. The red color is the signal, and the blue color is the derivative of the signal (basically a slope at that moment…
- In Clarity, up to 4 independent configurations can be set up - one on each available Instrument with an independent time-base. Up to 32 signals/channels can be acquired on one Instrument. The…
- If your PC and chromatograph are connected directly via LAN and autodetect is not possible, continue with the following procedure:You need a cross-over ethernet cable (a straight-through cable is not…
- A Connect key is needed to activate communication between Clarity and Nexera control module. The Connect key (text file) will be generated by Shimadzu support upon providing the following…
- A user needs to fill out the "Registration of a university package" form that is available on our website. A description of the registration procedure is a part of Clarity Offline delivery.
- The Clarity software license is fixed on the HW key. The software itself could be installed freely on different computers, but without the HW key, it will not start.To move Clarity to a new PC,…
- If it is required to print the audit trail of the method (*.met) file, it is necessary to perform this print directly from the Method Setup dialog, where the correct method is opened. Report style…
- State of Clarity Instrument can be read by other software using a built-in DDE server. For more information, please see the datasheet D070 DDE synchronization of Clarity with other programs.
- During acquisition, data are stored in the temporary directory (...\TMP\ $ch1run.raw file ). The data are stored from memory to disk in approximately 1 min intervals. In case the Clarity crashes/…
- The sample rate needs to be set to provide enough points to describe the peaks of interest adequately. It is recommended that at least 30 points be reached per the narrowest peak width. The default…
- LAN communicationGeneral issuesFor LAN communication, one of the 1100/1200 modules must be equipped with a LAN communication card inserted in the MIO slot on the backside of the module (do not…
- It is possible to schedule a task that will run Clarity with defined parameters automatically starting a sequence. Proceed as follows:Prepare a batch file (clarity.bat) to perform the required tasks…
- If you purchase a software upgrade for your Clarity or Clarity Lite Software license, you will get a free upgrade for your associated free Clarity Offline. You only need to list the Clarity Offline S…
- In such case, it is recommended to check Colibrick Setup in the System Configuration window. Synchronize Start with Digital Input should only be enabled when one of…
- Yes, you can. There are two possible intentions of using the sequence table for starting the acquisition:Using sequence for manual injectionsYou could define parameters for a series of injections in…
- For the Gow-Mac GC chromatograph, use the asymmetrical connection as shown in the picture below.Connect Brown wire (pink tubular end sleeve) to terminal (+) and white wire (grey tubular end sleeve)…
- This situation is unpleasant because the loss of the HW key equals the loss of the license. The software and a new HW key must be repurchased.We include warning labels attached to HW keys in each…
- Most probably, you need an appropriate User Code (u/c) only. HW key keeps the basic information about serial number XX-YYYYY (event. XX-YYYYYY) only. All information about valid versions, a number of…
- Moving Clarity to a new PC is definitely possible – there are just a few things you’ll need to check:Clarity version: Older versions may not run on modern Windows systems. You might need to purchase…
- This usually happens when upgrading Clarity from an earlier version. The IQ program checks all registered files and, if they are no longer used in the new version, will cause the check to fail.…
- It is not possible to install Clarity on Windows 10 LTSC releases, where .NET Framework version 4.8 or newer cannot be installed (this should apply to Windows 10 Enterprise LTSC 2015). Clarity…
- Yes, it is. Simply take your HW key and plug it into another PC. You can install Clarity (Lite, Offline) on as many PCs as you like using the same user code. Clarity will work properly on the one PC…
- Most probably, yes, the list contains only directly controlled autosamplers. In other words, those where it is possible to set the position and injection method using a computer.…
- Yes, since Clarity 8.0 you can work with up to 10 internal standards.
- InstallationInstallation to program files: In Windows 7, the folder Program files is protected, however, Clarity needs user access to the data and system files. It is not recommended to install…
- Clarity installation requires a specific version of Microsoft .NET Framework, which may not be installed or enabled on the computer by default. You will be notified by the Clarity installer which…
- Windows 10 and 11 rolled out updates that change some behavior in the registry, which in some cases (mainly when Clarity installation has been run recently) causes installation not to start. Problem…
- The error message pops up after the start of Clarity. This problem is caused by the wrong configuration file saved in Clarity\cfg. The most common reason is that the computer was shut down while…
- Clarity stores the IP address of the device detected during autodetection in the configuration and if it changes, it is unable to communicate with the device. Some devices use IP adress assigned by…
- If you experience a long delay when downloading the Clarity installer from www.dataapex.com and the download process seems to hang when it's almost complete, it's possible that your anti-virus…
- When Clarity (Lite) is started, an error message stating "Missing HW key" may appear. This issue arises when the required hardware key is not detected by the system.If you encounter any problems, the…
- If you add a User Column to both the Summary and Result Table containing the same formula, often you cannot get the same results. You cannot use the First, Last, etc. functions from Special Values in…
- Most problems with Colibrick are related to the USB power supply. So if USB hub is used, we recommend using a hub with an external power source.It's important to note that Colibrick is sensitive to…
- We can offer Clarity (Lite) with analog data acquisition for each chromatograph and A/D converter Colibrick. Chromatographs/detectors need a standard analog output and means for local control, e.g.,…
- The Clarity software has several system files that are important for storing various data related to its functioning. The list of the files with default paths:C:\Clarity\Cfg\Clarity.cfgThis file…
- A Clarity Control Module is an optional software module that enables autosampler, GC, GC-MS, HPLC/CE, or HPLC-MS control. Clarity can control chromatographic hardware listed in the datasheet List of…
- Clarity Extension is an optional software extension that brings additional capabilities to Clarity. The information about available extensions, including technical documentation, can be found on our…