8.1.0

*New: Control: Testing - Agilent ICF - support for injection overlap for selected samplers is available for testing.

*New: Control: Testing - Analytical Technologies Ltd. - iUHPLC Series 3000Plus control modules (pumps, detector, thermostat) are available for testing.

*New: Control: Testing - Analytik Jena - PlasmaQuant ICP-MS control module is available for testing.

*New: Control: Testing - Fuli GC 9720 Plus control module is available for testing.

*New: Control: Testing - PerkinElmer - NexSAR HPLC System (including NexION ICP-MS detector) control module is available for testing.

*New: Control: Testing - YL Instruments - YL9150 Plus AS control module is available for testing.

*New: Control: Updated drivers - Agilent ICF libraries have been updated to version A.02.05.

*New: Control: Updated drivers - CTC-PAL3 driver has been updated to version 1.1.0.18.

*New: Control: Updated drivers - Ecom ECD 2000 to 3.4.0.0, ECF 2000 to 1.6.0.0, ECDA 2000 to 2.4.0.0, ECO 2000 to 2.8.0.0, ECP 2000 to 3.4.0.0, Flash 06 DAD to 2.5.0.0, Flash 12 DAD to 2.5.0.0, Iota to 2.6.0.0, Panda-30 HID to 1.9.0.0.

*New: Control: Updated drivers - FTDI drivers (used in several control modules) were updated to version 2.12.28.

*New: Control: Updated drivers - YL Instrument drivers have been updated: YL6500 GC to version 1.0.1.11, YL9110 Pump to version 4.0.3.9, YL9120 Detector to version 4.0.3.13, YL9130 Thermostat to version 4.0.1.10.

*New: Control: Fuli GC9720 control module removed from installation.

*New: Control: Initial value for Max. Pressure in the Set Flow dialog (invoked from Device Monitor) can be set in the method (Method Setup - LC Gradient tab - Options...).

*New: Control: UNI-RUBY control - used com port will be closed at closing the instrument window (before at closing entire station).

*New: Extension MS: Better distinguished Result Table Signals in the Summary Table.

*New: Extension MS: Enhanced Peak Tags option disabled (was not functioning correctly).

*New: Extension MS: Function Show Spectrum now displays spectrum prior to selecting it from the chromatogram, i.e. easily overview the whole spectrum.

*New: Extension MS: Improved handling of MS chromatograms - decreased time to open a chromatogram.

*New: Extension MS: Improved synchronization between peak selected in chromatogram and compound selected in the Result Table and MS Method.

*New: Extension MS: Min. Match Factor on Target Compound Search now allows to enter precise value.

*New: Extension MS: New option to Add m/z signal manually.

*New: GUI: System Configuration dialog is now re-sizeable.

*New: Chromatogram: Added support for User Columns using contextual menu (right mouse click) in the Summary Table.

*New: Instrument window: Commands for running analyses and sending methods were added into the Instrument window. They change dynamically, allowing to Stop or Abort running analysis.

*New: Instrument window: Pre-configured toolbar to control acquisition directly from the Instrument window.

*New: Instrument window: Tooltips have been improved.

*New: New folder Documentation in the Clarity installation structure (includes manuals and datasheets moved from \BIN\DOC_PDF folder).

#Fixed Bug: Control: Advantec - CHF122SC possible communication error at end of sequence.

#Fixed Bug: Control: Foxy 200 possible communication errors.

#Fixed Bug: Control: Fraction collectors in UNI-RUBY - misleading message about missing signal when signal name was changed.

#Fixed Bug: Control: HTA HT3x00A sampler incorrect injection speed limits.

#Fixed Bug: Control: LC Gradient not functional Initial-Standby mode (introduced in version 7.3).

#Fixed Bug: Control: Sykam S2100 pump - pump switched off after finished analysis regardless of the setting in the Idle flow options (introduced in 8.0).

#Fixed Bug: Control: Sykam S2100 pump had problems in gradient control.

#Fixed Bug: Control: Teledyne ISCO - Foxy 200 problems with control from device monitor.

#Fixed Bug: Control: UNI-Ruby - temporary freeze during communication error with UNI-Ruby controlled pumps.

#Fixed Bug: Audit Trail: logging of changes in calibration did not report certain changes.

#Fixed Bug: Calibration: compound tab, level RSTD calculation wrongly included recalibrations marked as unused.

#Fixed Bug: Extension MS: Memory leaks during switching rows in the Calibration Table.

#Fixed Bug: Extension MS: problems with printing of freshly acquired chromatograms.

#Fixed Bug: Extension PDA, MS: Spectral data were not created in case the spectrum had more than 1000 points.

#Fixed Bug: Extension PDA: Nonfunctional icon for Print in PDA window

#Fixed Bug: GUI: Instrument window was stealing focus during post run print operations.

#Fixed Bug: Chromatogram: Event table resets the set valve positions (introduced in 8.0).

#Fixed Bug: Chromatogram: Integration table, some parameters displayed mV instead of detector signal units.

#Fixed Bug: Chromatogram: Wrong export of user columns for multisignal chromatograms (introduced in version 7.4.).

#Fixed Bug: Import: the importing of chromatogram in txt format failed in some cases.

#Fixed Bug: Installation: Driver uninstallation failed in some situations.

#Fixed Bug: Instrument window: possible crash when opening Method Setup from menu.

#Fixed Bug: Other: Sample dilution allowed to set zero value (introduced in 8.0).

#Fixed Bug: Other: When adjusting width of multiple selected columns in tables, changes were stored only for the active column.

#Fixed Bug: Other: Window focus lost when toolbar tooltip from window behind was displayed.