Clarity Chromatography Software - Screenshots

Clarity window

Clarity main window

 

The Clarity window is an entrance point to individual chromatography systems. Depending on the configuration users can acquire data from up to 48 detectors configured on four independent Instruments.

See Also: Clarity - Example of two instrument configuration

Instrument window

Clarity Instrument

 

The Instrument window is the control center of the whole process of data acquisition and evaluation. It includes information table displaying the processed sample: name, applied template method, acquisition mode, etc. The status line indicates the current state of the analysis: elapsed time and state. The analysis-processing diagram provides icons for fast access to every process of the whole procedure.

See Also: Instrument window tutorial

Chromatogram window

Chromatogram window

 

The Chromatogram window displays the chromatogram and results. Users can easily edit acquired chromatograms visually in the graph or through Integration table.
The Result tables (Results, Summary, Column Performance, etc.) can be easily customized to display the data you want see exactly in the way you want to see them.
The Summary tab displays data from overlaid chromatograms in one table for easy comparison.

Calibration window

Calibration window

 

The Calibration window has two main screens, a global calibration table and dedicated tabs for each compound (on the screenshot)
The compound tabs contain a table with concentration levels matching the response with Amount and a calibration curve.
Any point can be temporarily suspended in the graph it is then marked with a circle instead of a cross.

Sequence

Sequence window

 

The Sequence table can be easily edited, using the fill down the user can easily compose the sequence with many injections. The status of each row is indicated by the colored symbols.

Device Monitor

Device Monitor

The Device Monitor lets you control parameters of your instruments during the analysis.

Event Table

Event Table

 

The Event table allows to control digital outputs, analysis, sequence or run a specified command based on events such change of state of digital input, signal level, analysis time, etc. The Colibrick A/D converter supplied by DataApex provide digital outputs that can be used for Start synchronization with other devices. These outputs can also be controlled from the Event Table. The setting on the image is used to control Fraction Collectors.