Changes in version 2.4.4.83 (09.11.2006 )
Main changes comparing to version 2.4.1 *New: Change to UNICODE character set. This change enables the localization of Clarity software to other languages including Chinese. As a consequence the system files (clarity.cfg, clarity.psw, all *.dsk files) are not backward compatible with previous versions. *New: Clarity EVAL solution was renamed to Clarity Offline to prevent confusion with the Demo version. *New: The Windows98/Me are no longer supported in Clarity version 2.4.2 and higher. Older versions (2.3.0 and 2.4.1) are still available for downloads. *New: Graph Properties: Peak Area Coloring - The area of peaks can be colored based on the color specified in calibration, and/or it can be used to highlight selected peak(s) *New: Method Setup window tabs were reorganized: - Event table is now common to all devices on the same Clarity Instrument and is displayed at special tab. - Event Table was moved from Method Setup - Acquisition to new Method Setup - Event Table tab - External Start options were moved from Method Setup - Acquisition to Method Setup - Measurement tab *New: Automatic recalibration at selected level is possible also in Single Analysis *New: Tables - new Fill Down function (CTRL+F) will copy content of current cell to all cells bellow it. In Start Vial column in Sequence table it will automatically increment values. *New: New Common columns in the Chromatogram - Summary table *New: In the single detector operation Clarity now does not use color in the header of calibration tables to indicate the columns that are detector specific. *New: Chromatogram - Results table: new columns "Start time" and "Stop Time" display retention time of peak start/end. Hidden by default *New: New "Compound Name" column in the Chromatogram - Performance table *New: Tables: automatic switching of the number format to exponential was suppressed. *New: The peak area coloring is indicated in the row header of the Result Table (Chromatogram window). *New: The Import Chromatogram dialog can now import multi-detector chromatograms from TXT format. *New: Possibility to export User Columns from the Results Table. *New: Export Data dialog - new checkbox "Summary" enables to export the Summary table. *New: The Summary Table is exported "as on screen" instead of fixed format *New: Export Chromatogram window contains new "Character Encoding" listbox. *New: Export Data dialog customizable setting of decimal separator. *New: Export Data to DBF format - repaired incompatibilities with DB III+ format specification. |
Changes in version 2.4.4.82 (09.11.2006 )
Main changes comparing to version 2.4.1 *New: The Run Again command is now available only when External Start setting in the Method Setup dialog is set to "Start-Restart". *New: Improved default chromatogram file naming template will provide unique filenames in every circumstance. *New: Possibility to see the name of template method used during chromatogram acquisition in the Chromatogram window. *New: Calibration Options dialog - Retention Index now has new option: Use Unretained Time. *New: The Noise value is now displayed more precisely (with tenths of µV) *New: The Injection Volumes can be now set in 1/1000 ml. (However it is still possible to switch to µl) *New: The new sequence is set to Active by default (according to the setting in template.seq in Common subfolder) *New: New command line parameter "stop" for stopping single analysis or sequence in progress. *New: New command line parameter export_run_time. *New: Better specified error messages related to trial period use. *New: The examples from the default installed projects (WORKX) were moved to the new projects (DEMOX). *New: Clarity SW folder reorganization - Clarity LC UNI driver profiles moved from CTRLLC to UTILS. *New: The documentation files installed with Clarity (DOC PDF folder) were unified and separated into corresponding subfolders. *New: The installation utility will detect previous installation of Clarity and offer to install into the same folder. *New: Installation of the free Adobe Acrobat Reader was included in the CD version of Clarity. #Fixed Bug: Printing from the sequence now prints only chromatograms opened in the Chromatogram window. #Fixed Bug: Printing of chromatogram did not always create a record in the Chromatogram history. Now it will even when the chromatogram was not changed. #Fixed Bug: The sequence ignored changes made in the Current value field in the Sequence Options dialog when the sequence was paused. #Fixed Bug: At certain situations the method was incorrectly marked as changed when closing the Method Setup dialog. #Fixed Bug: Paste Insert command inserted new line before the row with focused cell instead of before the selected line. #Fixed Bug: The formula for calculation of Standard Deviation in User Columns was changed to more common type. #Fixed Bug: The Run button in Data Acquisition window was inactive during single run. #Fixed Bug: The Paused and Idle Sequence statuses were incorrectly turned to Waiting when the related template method was edited. #Fixed Bug: Calibration automatic, the Add Single Peak command created separate level for each peak created from the same chromatogram. #Fixed Bug: The time axis in the Data Export were exported with 3 decimal places precision only, now it is 5 decimal places. #Fixed Bug: The values pasted to the tables in the Calibration window were rounded to 3 decimal places regardless the global setting. #Fixed Bug: The printout of summary table was not entirely WYSIWYG. #Fixed Bug: Improvements in Clarity command line support. |
Changes in version 2.4.4.105 (05.01.2007 )
#Fixed Bug: Mathematical Operation: when subtracting chromatograms with two signals the display of the first signal was suppressed.
|
Last updated: 2007-01-05 | webmaster

Version history 