Changes in version 2.3.0.174 (04.11.2004 )
# Fixed Bug: The Signal in Data Acquisition window did not display after positive exceeding the Range (Over) # Fixed Bug: At certain conditions the values indicated in the status bar of Data Acquisition window were not updated # Fixed Bug: Updated UPAD driver (necessary for Windows XP with Service Pack 2) # Fixed Bug: Minor amendments in printing # Fixed Bug: It was not possible to set external start after disabling the first detector in the Method Setup dialog # Fixed Bug: Systemizing the behavior of the Event Table for digital output and external program # Fixed Bug: Corrected malfunction of Save As Chromatogram command when using the Subtract Chromatogram feature # Fixed Bug: Minor amendments of mathematical operations with chromatograms |
Changes in version 2.3.0.162 (31.08.2004 )
# Fixed Bug: Accidental delay (0-1.2s) between the channels of U-PAD converter in case of synchronous acquisition # Fixed Bug: Inaccuracy in the printing of the calibration curve when using the "Use User Options" checkbox # Fixed Bug: Incorrect results in ISTD Calculation when the calibration curve cannot be constructed # Fixed Bug: The delay on the chromatogram's Time Axis (~20-200ms depending on the Sample Rate) has been compensated. # Fixed Bug: Minor amendments in Event table |
Changes in version 2.3.0.146 (28.06.2004 )------------------- Changes in the version 2.3 comparing to the version 2.2 ---------------------- * Calibration – Calibration points history * Calibration – Calibration table displays deviations of all calibration points * Calibration – Calibration displays a calibration curve residuum calculation * Print – Images ( picture, logo) in report header * Print – Option for printing an active signal (detector) or all signals * Print – Option for Black and White print * Print – Option for signals ( chromatograms) separate printing in one protocol * Event table – Option for an external program Run * Event table – Option for Puls Output level * Summary table – Extended option for Summary table layout * Summary Table – Displays the same colums as displayed in Results table * Acquisition – Option for data acquisition from only selected detectors directy from Method * Acquisition – New variable for automated chromatogram naming %Q –Sample, %q - Sample ID * Acquisition – Option for actual noise level in Data Acquisition Window * Chromatogram – Move and Scale commands applied to all signal from multidetector chromatograms using Shift key at a time --------------------------------------------------------------------------------------------------- |
Last updated: 2004-11-04 | webmaster

Version history 