Version history

 
 
 
 

Changes in version 4.0.0 (15.5.2012)

Known limitations of the current Beta version:

  1. CTC-PAL does not support overlapped samples. During uninstallation it locks on removing the CTC-SDK folder (install next version without uninstalling).
  2. There is a temporary listbox for selection of integration algorithm between old (3.0 or older) and new (4.0) version.
  3. The calibration files created or edited in this version could not be opened in previous versions

New features and improvements

*New: The Windows 2000 are no longer supported in Clarity version 4.0 and higher.  Older versions are still available for downloads.
*New: Command Chromatogram - Baseline - Allow Crossing enables the intersection of the signal with the baseline.
*New: LC Control: UNI LC pump control module was replaced by UNI RUBY scripts for selected pump models. This control enables features that were not supported by the UNI LC pump.
*New: Hardware: new external A/D Converter Colibrick.
*New: LC Control: Agilent HPLC control by ICF (Agilent Instrument Control Framework) covers 1100/1200/1260/1290 series.
*New: Extension DHA: (Detailed Hydrocarbon Analysis according to ASTM6730) is available for testing.
*New: Clarity - Localization to Spanish.
*New: LC Control: UNI RUBY scripts will now enable to control other device types (Pump, Detector, Valve, Fraction Collector). Support available for external developers.
*New: Data Acquisition window: View menu - includes the Set Axes Ranges command for setting the ranges for detector and auxiliary signals.
*New: Integration - New filters Moving Average and Savicky-Golay.  Value n corresponds to  the number of points used by (2n+1).
*New: AS Control: Spark SPH 1240 - Pumps module has been released.
*New: FC Control: General Purpose Fraction Collector module was replaced by UNI RUBY script.
*New: The Auxiliary Signals tab in the Chromatogram Graph Properties serves for setting the Auxiliary Signals axis range.
*New: DET Control: Grace Alltech 3300 ELSD detector control module has been released.
*New: AS Control: Cetac AS800 autosampler control module is available for testing.
*New: The Spike Removal command will replace spike (peak) in selected interval by estimated baseline curve.  This function can be blocked in GLP options (blocking not yet implemented).  The Spike Filter command, will remove narrow (electronic) spikes, parameter range is 1-100 corresponding to number of points processed.
*New: AS Control: HTA HT3x0A autosampler control in development stage.
*New: Support for Bar Code Readers  - new variable %f in the filename and other fields that will be replaced with the reader input.
*New: Data Acquisition window: improved auto scaling of the signal outside acquisition.
*New: AS Control: CTC PAL - new version of control libraries (ICC-CE) 1.6.0.5.
*New: Sequence - when relative path is used in chromatogram file name, corresponding subdirectory will be created in the corresponding project subfolder.
*New: Report setup, Chromatogram, Print range new command Preview and Detail will print the entire chromatogram and selected detail as two graphs (sharing the same settings).
*New: FC Control: UNI RUBY script for Fraction Collector by multi-position valve - Upchurch.
*New: Chromatogram window new option Perform Postrun to perform postrun actions (prints and exports) by single click.
*New: LC Control: UNI RUBY script for LabAlliance pumps.
*New: AS Control: Option to enter vial positions in alphanumeric format in selected samplers.
*New: Graph Properties - Signals dialog: the Grey Out Inactive Signals command applies to inactive signals in Overlay mode.
*New: FC Control: Gilson FC203 fraction collector control by UNI Ruby script.
*New: LC Control: The Knauer Optimas autosampler module has been released.
*New: Updated and new Ecom control modules.
*New: Balance Control: Mettler-Toledo Excellence ballances Control module for Clarity with EA Extension has been released.
*New: Option to prolong/renew expired Trial mode in RkNDUSB HW keys.
*New: GC Control: Agilent G2880A 6850 ALS supported within the 68xx GC control driver.
*New: Chromatogram export to AIA - header now includes detector (signal) name.
*New: LC Control: VICI Valco multi-position valve control as fraction collector by UNI RUBY script.
*New: Integration - Interval operations are performed on peaks with apex within the set interval (Previously entire peak had to be included).
*New: Minor improvements of User Interface.
*New: LC Control: Vici Valco - the new Universal Actuator now supported.
*New: Option in the Login dialog Project selection listbox to create a new project during opening the instrument.
*New: Kontron 360 Autosampler by UNI-Ruby is now available for testing.
*New: Hardware: Updated drivers for U-PAD2, Colibrick, OPTUSB a MULTICOM.
*New: GC Control: Updated drivers for DANI Master GC (version 1.4.4.0) and Master DHS (version 1.0.1.0).
*New: GC Control: Agilent 68x0 - option to set up carrier gas from configuration.
*New: Clarity registration form - could be printed and sent by fax if internet connection is not available.
*New: AS Control: CTC-PAL support for 5 µl and 1.2 µl syringes.
*New: LC Control: Gradient, graph is displayed including region before start.
*New: LC Control: Gilson pump control will not use GSIOC server anymore, so it is functioning also on Windows Vista and Windows 7.
*New: Extensions: New instrument type "CE-PDA" is available in the System Configuration dialog.
*New: Improved formatting of the Note field in reports.
*New: Virtual digital input output loop - option to specify number of devices. When more devices are specified, they could be used on multiple instruments to synchronize them, but the Delay command in the Method Setup will not be supported.
*New: The run_seq commandline parameter corrected. The new resume_seq for resuming running sequence.
*New: Print Icon on toolbars now prints directly, without offering the printer selection dialog. Not implemented in Audit Trail Window.
*New: AS Control: Shimadzu AOC20i - support for three solvents for wash.
*New: Available Control Modules – indication of available, but not installed modules was added.  
*New: FC Control: Teledyne ISCO Foxy R1 fraction collector control by UNI-RUBY script.
*New: LC Control: Flom pump control by UNI-RUBY script.
*New: LC Control: Omniseparo M350 pump control by UNI-RUBY script.
*New: AS Control: Spark Allias II - Setting of the Injection Volume.
*New: User Options dialog: "Warn before running already measured sequence" is now active in default desktop.
*New: The Filter command (Chromatogram Window, Edit menu), intended to hide redundant lines in integration table has been discontinued.
*New: The UNI Ruby Control module framework supports GSOIC.
*New: Method Setup - Event table: new event Ready  triggered when all hardware on instrument reports ready.
*New: The Perform Postrun window now includes the Sign button for signing the performed operations.
*New: Calibration - new peak names are created with three decimals instead of 2, that means "Peak 14.935" instead  "Peak 14.93". To avoid conflicts in high speed analyses.
*New: Tables - right click on row/column header will select the corresponding row. Right click on upper-left corner cell will select entire table.
*New: Clarity - Localization to German.
*New: Hardware: MultiCOM - updated drivers.
*New: AS Control: Knauer Optimas control module has been released.
*New: LC Control: Driver for all Knauer Instruments updated to version 3.0.7.3055.
*New: DET Control: Knauer control modules detectors  10D/UVD2.1 and Conductivity Monitor 2900.
#Fixed Bug: Possible crash when active chromatogram was changed and automatically opened in the Chromatogram window during Library search operations in the PDA window.
#Fixed Bug: CTC-PAL - set injection volume will be rounded to nearest integer.
#Fixed Bug: The format of calibration file has been optimized. It decreased its size and sped up its processing. The new *.cal files are not compatible with previous Clarity versions.
#Fixed Bug: Data Acquisition window: Updating of signals during run.
#Fixed Bug: Chromatogram, Properties, Signals - improved options for scaling. Settings for Maximum and Minimum are now independent to better cope with negative peaks.
#Fixed Bug: Import CDF - improved detection of data range.
#Fixed Bug: The Store checkboxes in the Auxiliary Signal table in the Method Setup - Advanced dialog were stored only after clicking the OK button.
#Fixed Bug: Data Acquisition window - problem with the "Minus" key on numeric Keypad in the signal/time edit box.
#Fixed Bug: Chromatogram window - improved behavior of the Open Chromatogram Sequentially browse buttons.
#Fixed Bug: The validation of No of points field in the Calibration Options dialog did not work properly.
#Fixed Bug: Changes in the chromatogram opened in Chromatogram and Calibration windows were lost when the Instrument window was closed directly.
#Fixed Bug: AIA export - attribute Retention_units was changed from Minutes to Seconds.
#Fixed Bug: LC Control: Agilent 1100/1200 DAD - Validity of wavelength and bandwidth were not performed in the Time Table.
#Fixed Bug: Updated dpinst.exe to solve some problems with driver installations.
#Fixed Bug: Extension EA - Analysis, Batch checkboxes can be now modified.
#Fixed Bug: GC Control: Shimadzu GC201x - the method with changed sample rate had to be sent twice to apply correctly.
#Fixed Bug: The graph signal properties were not stored in the Graph Properties.
#Fixed Bug: Data Acquisition window - delayed drawing of signals.
#Fixed Bug: Extension GPC: Chromatogram - GPC Results: the equation above the GPC Results table was not displayed on certain conditions.
#Fixed Bug: Chromatogram: very low value of threshold was displayed as zero value.
#Fixed Bug: Extension GPC: Slice table - error in displayed response (slice height) values.
#Fixed Bug: Chromatogram: The Column Performance Table did not detect the situation, when there were no peaks in the chromatogram.
#Fixed Bug: LC Control: Mismatch in displayed number of decimal places in individual filed of the Gradient table.
#Fixed Bug: Chromatogram: The rotated text labels in graph persisted in display after they were deleted.
#Fixed Bug: Export Data dialog: certain settings were not stored properly.
#Fixed Bug: Corrupted unload splash screen appeared when the Clarity main window was partly off the monitor.
#Fixed Bug: Chromatogram measured with fraction collector incorrectly indicated to be modified after each opening.
#Fixed Bug: Exporting data in Postrun occasionally switched signals.
#Fixed Bug: AS Control: Spark 1240 pump valves now cannot switch solvent during analysis (limitation of the device).
#Fixed Bug: Data Acquisition window: it was not possible to modify the axes ranges after Abort of the analysis.
#Fixed Bug: The Message boxes were larger than necessary.
#Fixed Bug: Sequence window: editing a row from which consecutively the analysis started caused that the cursor freezed up in the table.
#Fixed Bug: Chromatogram: checking the "Use User Options" while having the graph zoomed caused incorrect behavior of the graph.
#Fixed Bug: PDA Window: the zooming and rotating the graph using the CTRL + mouse shortcut did not work.
#Fixed Bug: Knauer Optimas, YL9151 - incorrect default tube volume.